Contact US

captcha

Oral/Enteral Syringes

  • 1 mL to 100 mL sizes avail­able
  • Includes self-righting tip cap neces­sary for adher­ence to aseptic tech­nique proto­cols
  • Low Dose syringes (1, 3, 6 mL) comply with recom­men­da­tions outlined by the August 2016 GEDSA Position Statement
  • FDA 510(k) clear­ance allows both enteral and direct oral admin­is­tra­tion.
  • Offset tip, solid plunger, and o-ring designs mini­mize lipid loss, maxi­mizing nutri­tion delivery
  • Our syringes are not made with BPA, DEHP, or Latex.

NeoMed's syringes are designed to work seamlessly with most new or existing pumps
on the market without introducing flow variances common with other oral dispensers.

Medfusion 3500 & 4000 V5
6, 12, 20, 35, 60, 100 mL

BBraun Perfusor
3, 6, 12, 20, 35, 60 mL

ABC 4100
3, 6, 12, 20, 35, 60, 100 mL

Medima S100 & Model S200
6, 12, 20, 35, 60 mL

Eccentric Tips have the lowest fat loss.

NeoMed funded an inde­pen­dent study* to look at fat loss in a variety of enteral syringe types. This study was part of a compre­hen­sive review of the design elements of syringes and fat loss during HBM delivery. The results of this inde­pen­dent study may have long range impli­ca­tions for the NICU and their choice of enteral delivery syringes: This study iden­ti­fied a statis­ti­cally signif­i­cant rela­tion­ship between fat loss in hori­zon­tally posi­tioned 60 mL syringes and aspects of their design.

6%
6%
11%
11%
13%
22%

Eccentric Tip with Flat Solid Polypropylene Plunger with O-Ring
■ Concentric Tip with Conical Elastometer Plunger Assembly

Off-Center syringe tips with solid piston design have fat loss of 6%.

Center syringe tips with elas­tomeric piston design have fat loss from 11% to 22%.

The solid polypropy­lene plunger head is flatter, creating less surface area for unwanted lipid/fat adhe­sion.

Rubber plunger tips are more conical, creating more surface area for unwanted lipid/fat adhe­sion.

*Wages SA. Examination of Fat Loss from Human Breast Milk in Oral/Enteral Syringes from Different Manufacturers. Alpharetta, GA: April 2014.

ENFit Self Righting Tip Cap
Self-righting plugged tip caps are designed to reduce exces­sive handling during assembly
Off Center NeoMed Syringe on Medfusion Pump
Off-set tip designed to deliver colostrum first when placed in pumps that have hori­zontal orien­ta­tions
Group of NeoConnect Syringes Purple
Bold grad­u­a­tion mark­ings facil­i­tate
accu­rate admin­is­tra­tion of nutri­tion
NeoConnect Syringes for ENFit Pump Validated
Validated in the Medfusion 3500 and 4000 and BBraun Perfusor pumps

Orange Sterile ENFit Syringes

Item # Product Code Description Units per Case
810001 NM-S1NC 1 mL 200
810002 NM-S3NC 3 mL 200
810003 NM-S6NC 6 mL 200
810004 NM-S12NC 12 mL 200
810005 NM-S20NC 20 mL 100
810006 NM-S35NC 35 mL 100
810007 NM-S60NC 60 mL 100
810008 NM-S100NCV 100 mL Vented 40
810009 NM-S20NCV 20 mL Vented 100

Purple Sterile ENFit Syringes

Item # Product Code Description Units per Case
811001 PNM-S1NC 1 mL 200
811002 PNM-S3NC 3 mL 200
811003 PNM-S6NC 6 mL 200
811004 PNM-S12NC 12 mL 200
811005 PNM-S20NC 20 mL 100
811006 PNM-S35NC 35 mL 100
811007 PNM-S60NC 60 mL 100
811008 PNM-S100NCV 100 mL Vented 40
811009 PNM-S20NCV 20 mL Vented 100
NeoConnect Syringes for ENFit Instructions for Use